E-9942
Order No. |
№ | ViBration Isolation Material Color |
Maximum Allowable Load (N) |
Resonant frequency [Hz] |
Target Vibration Frequency [Hz] |
Vibration Isolation Material Deformation [mm] |
Weight (g) |
Drawing | Product BOX |
CAD | Production | Stock Status |
---|---|---|---|---|---|---|---|---|---|---|---|---|
109438 | BBH100D013 | Dark yellow | 400~900 | 9 | 17~ | 4 | 1.6 | View | Add | DATA | × | Stock〇 |
109439 | BBH100D030 | Dark gree | 880~1900 | 8 | 17~ | 4 | 1.7 | View | Add | DATA | × | Stock△ |
109440 | BBH100D060 | Dark Blue | 1700~3900 | 8 | 17~ | 5 | 1.7 | View | Add | DATA | × | Stock△ |
109441 | BBH100D130 | Purple | 2100~5000 | 9 | 18~ | 4 | 1.7 | View | Add | DATA | × | Stock〇 |
109442 | BBH140D007 | Pink | 440~980 | 7 | 15~ | 5 | 3.5 | View | Add | DATA | × | Stock△ |
109443 | BBH140D013 | Dark yellow | 830~1800 | 7 | 15~ | 5 | 3.5 | View | Add | DATA | × | Stock△ |
109444 | BBH140D030 | Dark gree | 1800~4200 | 7 | 14~ | 6 | 3.7 | View | Add | DATA | × | Stock△ |
109445 | BBH140D060 | Dark Blue | 3600~8200 | 7 | 14~ | 6 | 3.8 | View | Add | DATA | × | Contact |
109446 | BBH140M097 | Dark magenta | 6500~14700 | 6 | 12~ | 9 | 3.9 | View | Add | DATA | × | Stock〇 |
For devices with a high center of gravity, swaying of the device can be reduced by installing anti-vibration products at a position near the center of gravity inside the device.
Read the resonant frequencies of the mounts depending on the load from the table on the left and select the mount where the resonant frequency is 1/2 (0.5 times) or less the frequency of the vibration you want to isolate.
Selection Examples
If you want to isolate the vibrations from a motor running at 2,400 rpm with a load of 500 N on each mount
■The vibration frequency generated by the motor is 2,400 rpm/60 seconds = 40Hz.
Therefore, select mounts that have a resonant frequency of 40 Hz/2 = 20 Hz or less.
■The BBH140D070 (resonant frequency of approx. 12 Hz with a 500 N load) or BBH100D013 (resonant frequency of approx. 13 Hz with a 500 N load) are suitable for this case.
・If the resonant frequency of the mount is 1/√2 (0.7) times or higher than the vibration frequency you want to eliminate, damping effect will not act and the vibrations will be amplified.
The mount should be used loaded under compression.
・It cannot be used with a tensile or shear load. (Refer to the examples above)
You should also ensure that the mounts are not loaded with tensile or shear loads during transport and storage. The mount may become damaged if subjected to tensile or shear loads.