Q-LOCK ELEMENTS PINS (Hydraulic Type, Double Action) 

E-9659H

Material
Main body : Stainless steel(SUS440C)
Heat treatment
Main body : Hardened(HRC55)
Feature
■Air blowing for checking seating.
■Stronger clamping force for heavy cutting.
■Both clamp/un-clamp by hydraulic. By switching valve,can be used for auto-jig exchanging system.

Specifi cations

Type Order No. No. Outer
Diameter
Pin
Diameter
Overall
diameter
weight
(kg)
Drawing Product
BOX
CAD Production Stock
Status
Locating pin 129619 QLH26DRP 60 26 45 0.4 View Add DATA Stock Item Stock〇
Locating pin 129620 QLH32DRP 72 32 51 0.6 View Add DATA Stock Item Stock△
Locating pin 129621 QLH40DRP 88 40 61.5 1 View Add DATA Stock Item Stock〇
Locating pin 129622 QLH48DRP 105 48 74 1.8 View Add DATA Stock Item Stock〇
Dia. Pin 129623 QLH26DDP 60 26 45 0.4 View Add DATA Stock Item Stock〇
Dia. Pin 129624 QLH32DDP 72 32 51 0.6 View Add DATA Stock Item Stock〇
Dia. Pin 129625 QLH40DDP 88 40 61.5 1 View Add DATA Stock Item Stock〇
Dia. Pin 129626 QLH48DDP 105 48 74 1.8 View Add DATA Stock Item Stock〇
Clamping pin 129627 QLH26DCP 60 24 45 0.4 View Add DATA Stock Item Stock〇
Clamping pin 129628 QLH32DCP 72 30 51 0.6 View Add DATA Stock Item Stock〇
Clamping pin 129629 QLH40DCP 88 37 61.5 1 View Add DATA Stock Item Stock△
Clamping pin 129630 QLH48DCP 105 45 74 1.8 View Add DATA Stock Item Stock〇

Usage


Quickest jig exchanges on Horizontal machining centers

Dimensions of mounting process

No. AH7 B C D E+0.30 F G
QLH26D 29 30 28.5 10 15 48 M5
QLH32D 35 36 34.5 10 15 58 M6
QLH40D 42 43 41.5 10 18 72 M6
QLH48D 53 54 52.5 10 21 87 M8

※Dia.pin’s top position and tapped hole are as per drawing, so machine tapped holes and port holes to follow the direction of dia.

※1.There are 2 air-blowing holes, so take use of one.
※2.Lift up port must be within area.
※3.O-ring contacted surface must be without burrs(roughness 6.3S or under)

Structural drawing

Specifi cations

Type Hydraulic type, double action
Drive system Clamping Hydraulic
Un-clamp
QLH26D*P QLH32D*P QLH40D*P QLH48D*P
Clamping force (kN) at 0.5MPa 3 7 10 16
Lift up force(kN) at 0.5MPa 1.5 2.7 4 6
Clamping stroke(mm) 4.5 5 6 7
Lift-up amount (mm) 1
Cylinder volume(cm3) Clamping side 0.7 1.5 2.6 4.3
Un-clamp side 1.4 2.7 4.8 8.6
Max. working pressure(MPa) 5
Min. working pressure(MPa) 2
Proof pressure(MPa) 7
Recommended air blowing pressure(MPa) 0.5
Fluid Dry air
Ambient temperature (℃) 0~65
Weight(kg) 0.4 0.6 1.0 1.8

 

Browsing history
Is there information you required?

Back to the top of this page