Q-LOCK ELEMENTS/PINS (HYDRAULIC TYPE DOUBLE ACTION)

E-9659H

Material
Main body:SCM42
Piston:SCM44
Steel ball:SUJ2 
Heat treatment
Main body:HRC55 heat treatment
Piston:HRC55 heat treatment
Steel balls:HRC62 heat treatment
Feature
■Clamping by hydraulic pressure.

* The below items will be discontinued, once the present stock run out.


PIN (HYDRAULIC Type DOUBLE ACTION) SPECIFICATIONS

Type Order
No.
No. Outer
Diameter
Pin Diameter Weight
(kg)
Drawing Product
BOX
CAD Production Stock
Status
Locating pin 971078 QLHM03RP 66 32 0.5 View Add DATA Discontinued Contact
Locating pin 968845 QLHM07RP 96 40 1.5 View Add DATA Discontinued Contact
Locating pin 968846 QLHM10RP 106 48 2.3 View Add DATA Discontinued Contact
Locating pin 968847 QLHM16RP 120 55 3.5 View Add DATA Discontinued Contact
Locating pin 968848 QLHM25RP 140 55 4.8 View Add DATA Discontinued Contact
Dia. pin 971079 QLHM03DP 66 32 0.5 View Add DATA Discontinued Contact
Dia. pin 968849 QLHM07DP 96 40 1.5 View Add DATA Discontinued Contact
Dia. pin 968850 QLHM10DP 106 48 2.3 View Add DATA Discontinued Contact
Dia. pin 968851 QLHM16DP 120 55 3.5 View Add DATA Discontinued Contact
Dia. pin 968852 QLHM25DP 140 55 4.8 View Add DATA Discontinued Contact
Clamp pin 971081 QLHM03CP 66 30 0.5 View Add DATA Discontinued Contact
Clamp pin 968853 QLHM07CP 96 39 1.5 View Add DATA Discontinued Contact
Clamp pin 968854 QLHM10CP 106 47 2.3 View Add DATA Discontinued Contact
Clamp pin 968855 QLHM16CP 120 54 3.5 View Add DATA Discontinued Contact
Clamp pin 968856 QLHM25CP 140 54 4.8 View Add DATA Discontinued Contact

Usage

Mounting Dimensions

No. A B H7 C D E F G H I J
QLHM03 43 42 41.5 12 31 54 25.5 25.5 M5 13
QLHM07 56 54 55 18 38 82 34 34 M6 15
QLHM10 66 64 65 20 41 88 38 44 M6 15
QLHM16 82 80 81 20 46 100 46 50 M8 20
QLHM25 92 90 91 20 51 116 54 58 M10 20

Section Drawing

Technical Data

Type Hydraulic Type Double Action
Drive Method Clamping Hydraulics
Unclamp
No. QLHM03 QLHM07 QLHM10 QLHM16 QLHM25
Clamping Force (kN) (at 5 MPa) 3 7 10 16 25
Cylinder Volume
(㎝ 3)
Clamp Side 2 3 6 10 13
Unclamp Side 3 5 7 13 16
Clamp Stroke (mm) 3 3 3.5 3.5 3.5
Liftup Amount (mm) (at 5 MPa) 2.5 2.5 3 3 3
Liftup Force (kN/piece) (at 5 MPa) 4.5 7.5 11 18.5 23
Minimum Operating Pressure When Unclamped (MPa) 2.5
Guaranteed Withstand Pressure (MPa) 10
Recommended Air Blow Pressure (MPa) 0.5
Ambient Operating Temperature (°C) 0-65
Normal Usage Pressure (MPa) 5

 