E-1126
| オーダー № |
№ | Load tolerance | Defl ection |
Natural frequency Hz |
Weight (g) |
Drawing | Product BOX |
CAD | Production | Stock Status |
|
|---|---|---|---|---|---|---|---|---|---|---|---|
| kgf | N | ||||||||||
| 169304 | BBU25-075V1 | 0.5to0.75 | 4.9to7.3 | 1.5to4.5 | 8to12 | 72 | View | Add | DATA | × | Contact |
| 169305 | BBU25-110V1 | 0.75to1.1 | 7.3to10.7 | 1.5to4.5 | 8to12 | 72 | View | Add | DATA | × | Contact |
| 169306 | BBU25-160V1 | 1.1to1.6 | 10.7to15.6 | 1.5to4.5 | 8to12 | 74 | View | Add | DATA | × | Contact |
| 169307 | BBU25-220V1 | 1.6to2.2 | 15.6to21.5 | 1.5to4.5 | 8to12 | 74 | View | Add | DATA | × | Contact |
| 169308 | BBU25-360V1 | 2.2to3.6 | 21.5to35.3 | 1.5to4.5 | 8to12 | 76 | View | Add | DATA | × | Contact |
| 169309 | BBU25-500V1 | 3.6to5 | 35.3to49 | 1.5to4.5 | 8to12 | 74 | View | Add | DATA | × | Contact |
| Order no. | № | Load tolerance | Defl ection |
Natural frequency Hz |
Weight (g) |
Drawing | Product BOX |
CAD | Production | Stock Status |
|
|---|---|---|---|---|---|---|---|---|---|---|---|
| kgf | N | ||||||||||
| 121525 | BBU25-075 | 0.5to0.75 | 4.9to7.3 | 1.5 to 4.5 | 8 to 12 | 72 | View | Add | DATA | Discontinued | Stock〇 |
| 121526 | BBU25-110 | 0.75to1.1 | 7.3to10.7 | 1.5 to 4.5 | 8 to 12 | 72 | View | Add | DATA | Discontinued | Contact |
| 121527 | BBU25-160 | 1.1to1.6 | 10.7to15.6 | 1.5 to 4.5 | 8 to 12 | 74 | View | Add | DATA | Discontinued | Stock△ |
| 121528 | BBU25-220 | 1.6to2.2 | 15.6to21.5 | 1.5 to 4.5 | 8 to 12 | 74 | View | Add | DATA | Discontinued | Stock△ |
| 121529 | BBU25-360 | 2.2to3.6 | 21.5to35.3 | 1.5 to 4.5 | 8 to 12 | 76 | View | Add | DATA | Discontinued | Contact |
| 121530 | BBU25-500 | 3.6to5 | 35.3to49 | 1.5 to 4.5 | 8 to 12 | 74 | View | Add | DATA | Discontinued | Stock〇 |
Select the mount with suitable load tolerance from the specifi cations sheet. Select the mount with the natural frequency of 1/2 or less of the vibration frequency you want to isolate or remove.
[Selection example]
If you want to isolate the vibrations from a pump running at 1,800 rpm with a load of 5 kg on each mount, the frequency of the vibrations produced by the pump is 1,800 rpm/60 seconds = 30 Hz. Therefore, a mount with a natural frequency of 30 Hz/2 = 15 Hz or less should be selected.
Vibration Transmissibility (Representative Data)

Aim:Remove vibrations for in-line electronic scales.
Method:Install 4 hybrid built-in vibration isolation mounts between the base and the electronic scale mounting plate.
Result:The vibrations aff ecting the in-line electronic scales were successfully removed.

Vibrations on Floor Vibrations on Electronic Scale Mounting Plate

・ If the vibration frequency is √2 times the natural frequency of the mount or less, the vibrations will be amplifi ed.
・ Install such that the load is in the vertical/compressive direction. If the mounted object is too light or a tensile load is applied, the mounted object will make contact with the stoppers and the vibration isolation eff ect will be lost.
・ The purpose of the stopper mechanism is to reduce the risk of falling over. It does not guarantee safety. No liability will be born for accidents or damages.