BUILT-IN VIBRATION ISOLATION MOUNT WITH STOPPER (Lightweight Typ

E-1124

Material
Plate:SPHC
Bolt:S20C
Surface treatment
Trivalent chromate plating
Feature
■Uses polyurethane foam material that can reduce vibrations even low frequency vibrations.
■Uses ether-based polyurethane that is resistant to water and ultraviolet light without quality deterioration unlike rubbers.
■Since adhesives are not used at the joints with the fittings, there is no need to worry about deterioration or peeling of joints.
■Equipped with a stopper mechanism for preventing the mounted equipment from falling over.

[Application]
■Isolating vibrations caused by vibrating equipment such as compressors, blowers, coolers, and electric motors.
■Removing vibrations transmitted to equipment that is sensitive to vibrations such as measurement instruments and microscopes.
※1 The resonant frequency is the calculated value when the maximum allowable load is applied.
※2 Applicable vibration frequency is vibration frequency which can be isolated. The estimated frequency is calculated such that the vibration in vertical direction can be decreased to 1/2 when maximum loading is applied.
※3 The vibration isolation material deformation is the calculated value when the maximum allowable load is applied.

Specifi cations

Order
No.
Color Deflection
T
Load tolerance Natural
frequency
Hz
Applicable
vibration
frequencies
Hz
Weight
(g)
Drawing Product
BOX
CAD Production Stock
Status
N kgf
121492 BBS20D007 Pink 2 11 to 16 1.2 to 1.7 14 ≧28 40 View Add DATA × Stock△
121493 BBS20D013 Yellow 2 23 to 31 2.4 to 3.2 15 ≧29 41 View Add DATA × Stock〇
121496 BBS20D030 Green 2 52 to 70 5.4 to 7.2 14 ≧27 41 View Add DATA × Stock△
121497 BBS20M097 Purple 2 130 to 180 14 to 19 13 ≧26 42 View Add DATA × Stock△
121498 BBS25D007 Pink 2 19 to 26 2 to 2.7 13 ≧25 65 View Add DATA × Stock〇
121499 BBS25D013 Yellow 2 37 to 50 3.8 to 5.1 13 ≧26 66 View Add DATA × Contact
121500 BBS25D030 Green 2 80 to 100 8.2 to 11 12 ≧25 68 View Add DATA × Stock△
121501 BBS25M097 Purple 3 210 to 290 22 to 30 12 ≧24 70 View Add DATA × Contact
121502 BBS30D007 Pink 2 28 to 38 2.9 to 3.9 11 ≧23 98 View Add DATA × Stock〇
121503 BBS30D013 Yellow 3 53 to 72 5.5 to7.4 12 ≧23 100 View Add DATA × Contact
121504 BBS30D030 Green 3 110 to 150 12.0 to 16.0 11 ≧22 102 View Add DATA × Stock〇
121505 BBS30M097 Purple 3 320 to 430 33 to 44 10 ≧21 106 View Add DATA × Stock〇
121506 BBS35D007 Pink 3 39 to 52 4 to 5.4 11 ≧21 154 View Add DATA × Stock△
121507 BBS35D013 Yellow 3 73 to 98 7.5 to 10 11 ≧22 156 View Add DATA × Stock△
121508 BBS35D030 Green 3 150 to 210 16 to 22 10 ≧21 160 View Add DATA × Contact
121509 BBS35M097 Purple 4 440 to 580 45 to 60 10 ≧20 166 View Add DATA × Stock〇
121510 BBS40D013 Yellow 3 95 to 120 9.7 to 13 10 ≧20 194 View Add DATA × Contact
121511 BBS40D030 Green 3 200 to 280 21 to 29 10 ≧19 199 View Add DATA × Contact

Usage

Selection Guide

From the graph showing the relationship between natural frequency of each mount and mounted load, select the mount with the
natural frequency of 1/2 or less of the vibration frequency you want to isolate or remove.

[Selection example]
If you want to isolate the vibrations from a pump running at 1,800 rpm with a load of 5 kg on each mount.
The frequency of the vibrations produced by the pump is 1,800 rpm/60 seconds = 30 Hz.
Therefore, a mount with a natural frequency of 30 Hz/2 = 15 Hz or less should be selected.
In this case, BBS25D013 (natural frequency of 13 Hz when under a load of 5 kg) and BBS35D007 (natural frequency of 11 Hz when under a load of 5 kg) are suitable.

Graph showing the relationship between natural frequency of each mount and mounted load

Application Examples

Aim:Isolate vibrations from a compressor
Method:Install 4 of the BBS35D013 built-in vibration isolation mounts with stopper between the compressor and the base.
Result:The vibrations transmitted from the compressor to the base were successfully reduced.
(The following graph shows the vibration acceleration in the vertical direction as measured at the top of the base.)

 Before installation                                                          After installation

Precautions for Use

・ If the vibration frequency is 2 times the natural frequency of the mount or less, the vibrations will be amplified.
・ Use the mounts inside the load tolerance range. Furthermore, install such that the load is in the vertical/compressive direction. If the load is too light or too heavy, or a tensile load is applied, the mounted object will make contact with the stoppers and the eff ectiveness will be lost. Furthermore, if the mounted object creates large vibrations, the mounted object may make contact with the stopper and might not be able to be used.
・ The purpose of the stopper mechanism is to reduce the risk of falling over. It does not guarantee safety. No liability will be born for accidents or damages.

Browsing history
Is there information you required?

Back to the top of this page