HYBRID BUILT-IN VIBRATION ISOLATION MOUNT(Lightweight Type)

E-1126

Material
Plate:SPHC
Bolt:S20C
Screw:SUS
Surface treatment
Trivalent chromate plating
Feature
■Hybrid structure that uses both a spring and vibration isolation material offers high vibration isolation effectiveness even with lightweight objects.
Furthermore, the damping effect of the vibration isolation material quickly stops swaying.
■Since the mount shape is the same regardless of the loading change, it’s easy to use for an object with unbalanced loading.
■Since adhesives are not used at the joints with the fittings, there is no need to worry about deterioration or peeling of joints.
■Equipped with a stopper mechanism for preventing the mounted equipment from falling over.

[Application]
■Removing vibrations transmitted to equipment that is sensitive to vibrations such as in-line inspection equipment, measurement instruments, and image processing equipment.
■Isolating vibrations caused by vibrating equipment such as small pumps, blowers, coolers, and electric motors.

※The deflection and natural frequency are calculated values.

Specifi cations

Order no. Load tolerance Defl
ection
Natural frequency
Hz
Weight
(g)
Drawing Product
BOX
Production Stock
Status
N kgf
121525 BBU25-075 4.91 to 7.36 0.5 to 0.75 1.5 to 4.5 8 to 12 72 View Add × Contact
121526 BBU25-110 7.36 to 10.8 0.75 to 1.1 1.5 to 4.5 8 to 12 72 View Add × Contact
121527 BBU25-160 10.8 to 15.7 1.1 to 1.6 1.5 to 4.5 8 to 12 74 View Add × Contact
121528 BBU25-220 15.7 to 21.6 1.6 to 2.2 1.5 to 4.5 8 to 12 74 View Add × Contact
121529 BBU25-360 21.6 to 35.3 2.2 to 3.6 1.5 to 4.5 8 to 12 76 View Add × Contact
121530 BBU25-500 35.3 to 49.1 3.6 to 5 1.5 to 4.5 8 to 12 74 View Add × Contact

Usage

Selection Guide

Select the mount with suitable load tolerance from the specifi cations sheet. Select the mount with the natural frequency of 1/2 or less of the vibration frequency you want to isolate or remove.

[Selection example]
If you want to isolate the vibrations from a pump running at 1,800 rpm with a load of 5 kg on each mount, the frequency of the vibrations produced by the pump is 1,800 rpm/60 seconds = 30 Hz. Therefore, a mount with a natural frequency of 30 Hz/2 = 15 Hz or less should be selected.

Vibration Transmissibility (Representative Data)

Application examples

Aim:Remove vibrations for in-line electronic scales.
Method:Install 4 hybrid built-in vibration isolation mounts between the base and the electronic scale mounting plate.
Result:The vibrations aff ecting the in-line electronic scales were successfully removed.

Vibrations on Floor                   Vibrations on Electronic Scale Mounting Plate

Precautions for Use

・ If the vibration frequency is √2 times the natural frequency of the mount or less, the vibrations will be amplifi ed.
・ Install such that the load is in the vertical/compressive direction. If the mounted object is too light or a tensile load is applied, the mounted object will make contact with the stoppers and the vibration isolation eff ect will be lost.
・ The purpose of the stopper mechanism is to reduce the risk of falling over. It does not guarantee safety. No liability will be born for accidents or damages.

Browsing history
Is there information you required?

Back to the top of this page